Search Contact Us About Nycoil Site Map
FRL
Accessories
 
 
 
 
L-Bracket

L-Bracket
L-Type Bracket: Use with existing Y-type Spacer and its hardware.
Spacer with L-Type Bracket: is a complete accessory that includes the
Y-type Spacer, O-rings and screws. It will tie two modular units together and
can be used for mounting the units.

L - Type Bracket - Spacer with L-Type Bracket Dimensions (inches)
L-Type Bracket Spacer w/L-Type Bracket Applicable Model
B210L Y2OL AC2000-01/02
B310L Y3OL AC3000-02/03
B410L Y4OL AC4000-04
B510L Y5OL AC4000-06
B610L Y6OL AC5000

T-Type Bracket

T-Type Bracket
T-Type Bracket: Use with existing Y-type Spacer and its hardware.
Spacer with T-Type Bracket: is a complete accessory that includes
the Y-type Spacer, O-rings and screws. It will tie two modular units
together and can be used for mounting the units.

T-Type Bracket - Spacer with T-Type Bracket Dimensions (inches)
T-Type
Bracket
P/N
Spacer w/T-Type Bracket Applicable Model
B210T Y20T AC2010-01/02
B310T Y30T AC3010-02/03
B410T Y40T AC4010-04
B510T Y50T AC4010-06

Y Type Bracket Y-Type Bracket: Used for tying two modular components together.

Y-Type Spacer (inches)
Model Applicable Model
Y20 AC2000-01/02
Y30 AC3000-02/03
Y40 AC4000-04
Y50 AC4000-06
Y60 AC5000-10

Mounting Bracket for Filter and/or Lubricator Mounting Bracket for Regulators & Piggyback "FR" Units:
Used for mounting "R" and "W" units.

Mounting Bracket for Regulators & "Piggyback" FR Units (inches)
Model Applicable Model
B220 AR2000, AW2000
B320 AR3000, AW3000
B420 AR4-5000, AW4000

Mounting Bracket for Filter and/or Lubricator Mounting Bracket for Filter and/or Lubricator:
Used for mounting "F" and "L" units individually.

Mounting Bracket for Filter and/or Lubricator (inches)
Model Mounting Screw Applicable Model
B240 M4x8 Pan Hd AF/AL2000
B340 M4x8 SHCS AF/AL3000
B440 M5x10 SHCS AF/AL4000-04
B540 M5x10 SHCS AF/AL4000-06
B640 M6x10 SHCS AF/AL5000

Pressure Gauges Pressure Gauges: The small control orifice in these gauges maintains
a steady pressure reading even in high vibration applications, making them
ideal for use with air compressors or other pneumatic devices.
  • All metal housing and bezel ring
  • All brass back mount pipe connection with small control orifice
  • Dual calibration (PSI & MPa)
  • 3-2-3% of full-scale accuracy
  • Polycarbonate lens

Pressure Gauge 0-150 PSI Calibration (inches)
Model Scale
Range
Port
NPT
Applicable
Model
G36-10-01 0-1.0 MPa (red) 1/8 2000 & 3000 series
G46-10-02 0-150 PSI (black) 1/4 4000 & 5000 series

Shut-Off Valves Shut-off Valves: Zinc die cast body and reinforced nylon knob assure long lasting durability as well as ergonomic operation.

3 Way Manual Shut-Off Valve VHS2000, 3000, 4000 (inches)
Model P, A Port
NPT
R Port
NPT
VHS2000-01 1/8 1/8
VHS2000-02 1/4 1/8
VHS3000-02 1/4 1/4
VHS3000-03 3/8 1/4
VHS4000-04 1/2 3/8
Shut-Off Valve with Lock Out Tab (inches)
Model P, A Port
NPT
R Port
NPT
VHL3000-03 3/8 1/4

Valve Open:
"P" In Port is OPEN to "A" Out Port
"R" Exhaust Port is CLOSED
Two (2) 1/8" NPT Gauge Ports are OPEN to Inlet Pressure

Valve Closed:
"P" In Port is Closed to "A" Out Port
"A" Out Port is connected to "R"
Exhaust Port and to the two (2) 1/8" NPT Gauge Ports

The significance of this type of porting function is "visual" safety. When the valve is "CLOSED," the pressure from the "downstream" side of the valve is exhausted and, if a pressure gauge is used in the gauge port, it will show the absence of pressure.
Pressure Switch Pressure Switch: The pressure switch is mounted to a "Y" type spacer
that can be used with existing brackets or clamps.

Pressure Switch Ordering Information (inches)
Model Applicable
Model
IS1000M-2Y AC2000
IS1000M-3Y AC3000
IS1000M-4Y AC4000-04
IS1000M-5Y AC4000-06
IS1000M-5Y AC5000

Specifications
  • Fluid: Filtered Compressed Air
  • Proof Pressure: 145 PSI
  • Max. Operating Pressure: 100 PSI
  • Setting Range (off): 15 - 60 PSI
  • Differential Pressure: Less than 12 PSI
  • Ambient and Media Temp.: 40°F - 140°F
  • Power Connection: 3 Ft. Lead

  • Type of Actuation: N.O.
  • Operating Voltage: 24 - 220V
  • Max. Operating Current: 1000 mA
  • Max. Switch Capacity: 10 W (VA)
  • Response Time: Less than 1.0ms
  Replacement Part List: The pressure switch is mounted to a "Y" type spacer
that can be used with existing brackets or clamps.

Replacement Parts List
Description Series Part Number
Filter Metal
Bowl Assembly
2000 MC200F
3000 MC300F
4000, 5000 & AFF MC400F
Filter Metal Bowl Assembly w/Auto Drain 2000 MC200FD
3000 MC300FD
4000 & 5000 MC400FD
Lubricator Metal Bowl Assembly 2000 MC200L
3000 MC300L
4000 & 5000 MC400L
Filter Element
5 micron
2000 11294-05B
3000 111511-05B
4000 11104-05B
5000 11173-05B
Filter Element
25 micron
2000 11294-25B
3000 111511-25B
4000 11104-25B
5000 11173-25B
Filter Element
50 micron
2000 11294-50B
3000 111511-50B
4000 11104-50B
5000 11173-50B

 
FRL
 
            
   About Us    Quotations    Literature    Directions    Site Map    Products © 2011 Nycoil   All Rights Reserved